Quality control at Umbrella Laboratories: no shortcuts.
Every Umbrella Labs compound is tested in-house with HPLC and LC-MS/MS, verified by independent analytical chemists and shipped with a lot-matched Certificate of Analysis. Here is exactly how that works.
Mislabeled research compounds are common
A 2017 study in the Journal of the American Medical Association bought SARM products online and tested them (Van Wagoner et al., JAMA, 2017). Most were mislabeled: many held a different compound, a different amount or no SARM at all. Our QA/QC process exists so that never happens to your research.
Why HPLC-UV alone is not enough
Many suppliers, including large chemical companies, test purity with HPLC and a UV detector only. It is quick and cheap, but it can lack sensitivity and specificity.
- Two different molecules can look alike to a UV detector, which leaves room for structural ambiguity.
- Check a supplier’s Certificate of Analysis and you will often see HPLC-UV and nothing else.
Our LC-MS/MS approach
We add tandem mass spectrometry (MS/MS) to every purity assessment.
- Many compounds share the same intact mass, so a single round of MS can still mislead.
- A second round breaks the molecule into fragments. The parent mass plus its unique fragment ions identifies and quantifies the compound with confidence.
- This matters most for SARMs, many of which exist as diastereomeric mixtures. Separating and measuring those mixtures takes sensitive equipment, such as our triple-quadrupole spectrometer.
Four checks on every lot
Each lot passes the same sequence before it goes on sale.
Sample purity
We measure the peak area percentage of the target compound.
Identity confirmation
Mass spectrometry checks the isotope pattern, molecular ion and adduct ions.
Peak purity confirmation
We cross-check 3D UV data against MS data.
Independent verification
Independent analytical chemists credentialed by the NCCCCE validate the results, which appear on the COA.
Instruments in our pipeline
Routine analysis runs on a range of Thermo Scientific and Agilent instruments. Method development, data processing and reporting run on fully licensed chromatography software that meets regulatory data-integrity requirements.
Mass spectrometry
3D trap LC-MS, linear ion trap LC-MS and triple quadrupole GC-MS, with ESI and APCI ion sources.
Chromatography
HPLC with UV detectors and nanoflow LC for separating closely related compounds and mixtures.
Checked twice, documented once
Umbrella Labs SARMs and peptides are validated by independent analytical chemists credentialed by the National Certification Commission in Chemistry and Chemical Engineering (NCCCCE). Their results appear on the Certificate of Analysis that ships in every box.
Want to see the paperwork before you buy? Visit our COA library to look up or request the Certificate of Analysis for any lot.
Questions about a COA or a test result?
Our team can explain any Certificate of Analysis, method or storage condition.